17, 16, 14.5, 12, 10 and 8 dB values available. |
 |
5 to 1,000 MHz frequency range. |
Available in bulk or tape and reel for automated placement. |
|
|
Suggested PC Board
Footprint |
Ceramic
Top View |
|
|
Side View |
|
|
|
Schematic
|
|
|
|
|
|
|
|
ELECTRICAL PERFORMANCE |
5 |
-1.3±0.2 |
-1.5 |
20 |
18 |
22 |
18 |
-8±0.2 |
-8.2 |
20 |
18 |
17 |
10 |
-1.3±0.2 |
-1.5 |
20 |
18 |
30 |
20 |
-8±0.2 |
-8.2 |
20 |
18 |
18 |
750 |
-1.6±0.2 |
-1.8 |
20 |
18 |
22 |
18 |
-8±0.2 |
-8±0.25 |
20 |
18 |
16 |
870 |
-1.6±0.2 |
-1.8 |
20 |
18 |
22 |
18 |
-8±0.2 |
-8±0.25 |
20 |
18 |
16 |
1000 |
-1.6±0.2 |
-1.9 |
20 |
18 |
22 |
18 |
-8±0.2 |
-8±0.3 |
20 |
18 |
17 |
5 |
-0.8±0.2 |
-1.0 |
20 |
18 |
22 |
20 |
-10.5±0.2 |
-10.7 |
20 |
18 |
26 |
10 |
-0.8±0.2 |
-1.0 |
22 |
20 |
22 |
20 |
-10.5±0.2 |
-10.7 |
20 |
18 |
26 |
750 |
-1.0±0.2 |
-1.2 |
20 |
18 |
20 |
18 |
-10.3±0.2 |
-10.3±0.3 |
18 |
16 |
17 |
870 |
-1.1±0.2 |
-1.3 |
20 |
18 |
20 |
18 |
-10.3±0.2 |
-10.3±0.3 |
18 |
16 |
16 |
1000 |
-1.2±0.2 |
-1.4 |
20 |
18 |
18 |
16 |
-10.3±0.2 |
-10.3±0.3 |
18 |
16 |
16 |
5 |
-0.6±0.2 |
-0.8 |
22 |
20 |
24 |
20 |
-12.2±0.2 |
-12.4 |
22 |
20 |
24 |
10 |
-0.6±0.2 |
-0.8 |
22 |
20 |
24 |
20 |
-12.2±0.2 |
-12.4 |
22 |
20 |
24 |
750 |
-0.9±0.2 |
-1.15 |
20 |
18 |
20 |
18 |
-12.1±0.2 |
-12.1±0.3
|
20 |
18 |
19 |
870 |
-1.0±0.2 |
-1.25 |
20 |
18 |
20 |
18 |
-12.1±0.2 |
-12.1±0.3 |
20 |
18 |
17 |
1000 |
-1.1±0.2 |
-1.35
|
20 |
18 |
20 |
18 |
-12.1±0.2 |
-12.1±0.3 |
20 |
18 |
15 |
5 |
-0.9±0.1 |
-1.05 |
20 |
18 |
20 |
18 |
-14.7±0.2 |
-14.9 |
18 |
17 |
26 |
10 |
-0.8±0.1 |
-0.9 |
22 |
18 |
22 |
18 |
-14.5±0.2 |
-14.7 |
20 |
18 |
26 |
750 |
-0.7±0.1 |
-0.8 |
24 |
20 |
30 |
20 |
-14.5±0.2 |
-14.7 |
24 |
20 |
13 |
870 |
-0.7±0.1 |
-0.8 |
30 |
20 |
30 |
20 |
-14.5±0.2 |
-14.7 |
24 |
20 |
13 |
1000 |
-0.7±0.1 |
-0.7±0.15 |
30 |
20 |
30 |
20 |
-14.5±0.2 |
-14.7 |
24 |
20 |
12 |
5 |
-0.6±0.1 |
-0.7 |
20 |
18 |
20 |
18 |
-16.1±0.2 |
-16.3 |
20 |
18 |
26 |
10 |
-0.6±0.1 |
-0.7 |
22 |
18 |
22 |
18 |
-16.0±0.2 |
-16.2 |
22 |
18 |
26 |
750 |
-0.6±0.1 |
-0.7 |
24 |
20 |
30 |
20 |
-16.0±0.2 |
-16.2 |
30 |
20 |
16 |
870 |
-0.6±0.1 |
-0.7 |
30 |
20 |
30 |
20 |
15.9±0.2 |
-15.9±0.25 |
30 |
20 |
15 |
1000 |
-0.6±0.1 |
-0.6±0.2 |
30 |
20 |
30 |
20 |
-15.9±0.2 |
-15.9±0.25 |
30 |
20 |
15 |
5 |
-0.4±0.1 |
-0.5 |
22 |
20 |
24 |
20 |
-17.3±0.2 |
-17.5 |
20 |
18 |
17 |
10 |
-0.4±0.1 |
-0.5 |
24 |
20 |
24 |
20 |
-17.2±0.2 |
-17.4 |
22 |
18 |
17 |
750 |
-0.4±0.1 |
-0.5 |
24 |
20 |
22 |
20 |
-17.2±0.2 |
-17.4 |
24 |
20 |
11 |
870 |
-0.5±0.1 |
-0.65 |
20 |
18 |
20 |
18 |
-17.2±0.2 |
-17.2±0.25 |
24 |
20 |
10 |
|
* Temperature data available upon request.
|
* Specifications subject to change without
notice. |
* When compared to competitive parts,
Communication Associates Inc.'s couplers typically have similar or
less insertion loss with significantly tighter tolerances.
|
* System impedance is determined by external
resistor. Data shown represents 75 Ohm enviroment. |
* "Out to Tap" data shown are
derived by subtracting "In to Tap" measurement from the
actual "Out to Tap" measurement. This is also sometimes
referred to as "directivity". |
|
|
Phone (256)
835-0900
Fax (256) 835-0992
E-mail us at sales@caisolutions.com
|